What you’ll explore
What if you cover half the hose opening? In this lab you put your thumb over a garden hose and test your intuition against a real physics simulation.
Challenge levels
- Thumb over half. Water flows at 12 L/min through a 16 mm hose. You cover the end so only HALF the opening is left. How many times faster does the water leave than it moves inside the hose?
- How far does it reach?. Same 12 L/min, now with an 8 mm nozzle, held level 1.0 m above the ground. How far from the nozzle does the jet land, in meters? (No air drag, g = 9.81 m/s²)
- Water the plant. A plant stands 2.5 m from the nozzle. Keep 12 L/min and the 1 m height, and choose the nozzle size so the jet lands on it (within 10 cm).
- What if it widens?. What if the middle of the hose is a section twice as wide (32 mm instead of 16 mm)? How fast does the water move there, compared with the normal hose? (Give the ratio.)
- Open the tap more. Back to the 8 mm nozzle at 1 m, but now the tap sends 24 L/min instead of 12. How far does the jet reach now, in meters?
Key ideas
Show the explanations (spoilers: try the levels first)
- Continuity: A₁v₁ = A₂v₂. The tap still sends 12 L every minute, so through half the area the water must go 2× as fast (about 1.0 → 2.0 m/s).
- Exit speed = Q/A = 0.0002 m³/s ÷ 5.03×10⁻⁵ m² ≈ 3.98 m/s. Falling 1 m takes √(2·1/9.81) ≈ 0.45 s, so it lands 3.98 × 0.45 ≈ 1.80 m out.
- For 2.5 m you need an exit speed of 2.5 ÷ 0.45 ≈ 5.5 m/s. With 12 L/min that means an opening of about 3.6×10⁻⁵ m², a diameter near 6.8 mm.
- A = πD²/4, so doubling D gives 4× the area. Same Q, so the water slows to ¼ of its speed in the wide part, then speeds back up when the hose narrows again.
- Doubling Q through the same opening doubles the exit speed (≈ 7.96 m/s). The fall time is still 0.45 s, so the jet reaches about 3.59 m, twice as far.
About the model
- Water is incompressible and the flow is steady, so the same volume per second Q passes every cross-section: A·v = Q. Each section has one average speed (no velocity profile, no turbulence).
- The tap is modeled as delivering a fixed flow Q (set in L/min). Real taps are pressure-limited: here the exit speed is capped at √(2P/ρ) (P = tap pressure, default 3 bar ≈ 24.5 m/s), and Q drops when the opening is tiny. Hose friction, which lowers the real limit further, is ignored.
- Hose layout: 1.2 m of hose, a 0.6 m middle section (its diameter can differ), 0.6 m of hose, then a 0.15 m nozzle, all level at height h. Sudden changes of diameter are treated as instant (no transition loss).
- A tracer drop is released at the tap end at t = 0 into water that is already flowing (so it starts moving at the hose speed). It rides the flow section by section, then leaves the nozzle horizontally and flies as a projectile with g = 9.81 m/s² and no air drag; it lands when it reaches ground level.
- Speeds shown are measured from the tracer (section length ÷ time spent in it); the landing distance is measured from the nozzle. The hose is drawn about 6× wider than real so its size changes are visible; the other small dots are more drops in the same steady flow.
Every number on screen comes from the simulation, and each lab passes automated checks against the physics formulas. Spotted a mistake? Tell us.