Bops Lab
Daily Lab

Bernoulli's principle

Read the pressure in a Venturi tube

Bops Lab

What you’ll explore

Fast water has LOW pressure? Then why does a hose nozzle push so hard? In this lab you read the pressure in a Venturi tube and test your intuition against a real physics simulation.

Challenge levels

  1. Squeeze the flow. Water flows at 60 L/min through a 40 mm pipe that narrows to a 20 mm throat. By how much does the pressure DROP in the throat compared with the inlet, in kPa? (If you think it rises, type a negative number.)
  2. Read the columns. Now 45 L/min through the same Venturi (40 mm → 20 mm). Open tubes stand on the inlet and the throat. How much lower is the water column over the throat, in cm?
  3. Build a flow meter. You want a 30 cm gap between the inlet and throat columns at 45 L/min (inlet 40 mm). Choose the throat diameter.
  4. What if the flow doubles?. At 30 L/min the throat drop is 1.19 kPa. What if you double the flow to 60 L/min through the same Venturi? What is the drop now, in kPa?
  5. After the throat. Back to 60 L/min. After the throat the pipe widens back to 40 mm. How much lower is the outlet pressure than the inlet pressure, in kPa? (No friction.)

Key ideas

Show the explanations (spoilers: try the levels first)
  • Half the diameter is a quarter of the area, so the water goes 4× faster: 0.80 → 3.18 m/s. Bernoulli: the drop is ½ρ(v₂² − v₁²) = ½·1000·(3.18² − 0.80²) ≈ 4.75 kPa.
  • Speeds 0.60 → 2.39 m/s. Δh = (v₂² − v₁²)/(2g) = (5.70 − 0.36)/19.62 ≈ 0.272 m, so the throat column stands about 27 cm lower.
  • A 30 cm gap needs v₂² − v₁² = 2g·0.30, so v₂ ≈ 2.50 m/s. At 45 L/min that means a throat area of 3.0 cm², a diameter near 19.5 mm. This is exactly how a Venturi flow meter works: read the gap, get the flow.
  • Every speed doubles, and ΔP = ½ρ(v₂² − v₁²) grows with the square: 4 × 1.19 ≈ 4.75 kPa. That is why a Venturi meter is very sensitive at high flow and weak at low flow.
  • P + ½ρv² stays constant along the pipe. At the outlet the bore is back to 40 mm, so the speed is back to 0.80 m/s and the pressure is back to the inlet value. Real Venturis lose about 10% to friction.

About the model

Every number on screen comes from the simulation, and each lab passes automated checks against the physics formulas. Spotted a mistake? Tell us.